M9 IP67

Female cable connector overmoulded, unshielded

back

Series 702

Number of contacts

Variant
Variant 3

Contacts: 3, female cable connector overmoulded, unshielded, cable length 2 m

Ordering number 79 1452 212 03
Connector locking system bolted
Termination molded on cable
Wire gauge (mm) 0,25 mm²
Wire gauge (AWG) 24
Cable outlet -
Cable length 2 m
Degree of protection IP67
Mechanical operation > 500 Mating cycles
Upper temperature 70 °C
Lower temperature -25 °C
Rated voltage 125 V
Rated impulse voltage 1500 V
Pollution degree 1
Overvoltage category II
Material group III
Rated current (40°C) 4 A
Volume resistivity ≤ 3 mΩ
Material of contact CuSn (Bronze)
Contact plating Au (gold)
Material of contact body PBT (UL 94 V-0)
Material of housing PUR
Cable data
material housing PUR
Insulation single lead PVC
Single lead structure 32 x 0,1 mm
Cable sheath Ø 4.5
Conductor resistance 72Ω/Km
Temperature range cable movable °C from -5
Temperature range cable movable °C to 70
Temperature range cable fixed °C from -25
Temperature range cable fixed °C to 70
Bending radius cable fixed Min. 22 mm
Bending radius cable movable Min. 45 mm

Contacts: 3, female cable connector overmoulded, unshielded, cable length 5m

Ordering number 79 1452 215 03
Connector locking system bolted
Termination molded on cable
Wire gauge (mm) 0,25 mm²
Wire gauge (AWG) 24
Cable outlet -
Cable length 5 m
Degree of protection IP67
Mechanical operation > 500 Mating cycles
Upper temperature 70 °C
Lower temperature -25 °C
Rated voltage 125 V
Rated impulse voltage 1500 V
Pollution degree 1
Overvoltage category II
Material group III
Rated current (40°C) 4 A
Volume resistivity ≤ 3 mΩ
Material of contact CuSn (Bronze)
Contact plating Au (gold)
Material of contact body PBT (UL 94 V-0)
Material of housing PUR
Cable data
material housing PUR
Insulation single lead PVC
Single lead structure 32 x 0,1 mm
Cable sheath Ø 4.5
Conductor resistance 72Ω/Km
Temperature range cable movable °C from -5
Temperature range cable movable °C to 70
Temperature range cable fixed °C from -25
Temperature range cable fixed °C to 70
Bending radius cable fixed Min. 22 mm
Bending radius cable movable Min. 45 mm
Variant 5

Contacts: 5, female cable connector overmoulded, unshielded, cable length 2 m

Ordering number 79 1456 212 05
Connector locking system bolted
Termination molded on cable
Wire gauge (mm) 0,25 mm²
Wire gauge (AWG) 24
Cable outlet -
Cable length 2 m
Degree of protection IP67
Mechanical operation > 500 Mating cycles
Upper temperature 70 °C
Lower temperature -25 °C
Rated voltage 125 V
Rated impulse voltage 1500 V
Pollution degree 1
Overvoltage category II
Material group III
Rated current (40°C) 3 A
Volume resistivity ≤ 3 mΩ
Material of contact CuSn (Bronze)
Contact plating Au (gold)
Material of contact body PBT (UL 94 V-0)
Material of housing PUR
Cable data
material housing PUR
Insulation single lead PVC
Single lead structure 32 x 0,1 mm
Cable sheath Ø 5
Conductor resistance 72Ω/Km
Temperature range cable movable °C from -5
Temperature range cable movable °C to 70
Temperature range cable fixed °C from -25
Temperature range cable fixed °C to 70
Bending radius cable fixed Min. 25 mm
Bending radius cable movable Min.50 mm

Contacts: 5, female cable connector overmoulded, unshielded, cable length 5m

Ordering number 79 1456 215 05
Connector locking system bolted
Termination molded on cable
Wire gauge (mm) 0,25 mm²
Wire gauge (AWG) 24
Cable outlet -
Cable length 5 m
Degree of protection IP67
Mechanical operation > 500 Mating cycles
Upper temperature 70 °C
Lower temperature -25 °C
Rated voltage 125 V
Rated impulse voltage 1500 V
Pollution degree 1
Overvoltage category II
Material group III
Rated current (40°C) 3 A
Volume resistivity ≤ 3 mΩ
Material of contact CuSn (Bronze)
Contact plating Au (gold)
Material of contact body PBT (UL 94 V-0)
Material of housing PUR
Cable data
material housing PUR
Insulation single lead PVC
Single lead structure 32 x 0,1 mm
Cable sheath Ø 5
Conductor resistance 72Ω/Km
Temperature range cable movable °C from -5
Temperature range cable movable °C to 70
Temperature range cable fixed °C from -25
Temperature range cable fixed °C to 70
Bending radius cable fixed Min. 25 mm
Bending radius cable movable Min. 50 mm
Variant 8

Contacts: 8, female cable connector overmoulded, unshielded, cable length 2 m

Ordering number 79 1462 212 08
Connector locking system bolted
Termination molded on cable
Wire gauge (mm) 0,14 mm²
Wire gauge (AWG) 26
Cable outlet -
Cable length 2 m
Degree of protection IP67
Mechanical operation > 500 Mating cycles
Upper temperature 70 °C
Lower temperature -25 °C
Rated voltage 125 V
Rated impulse voltage 1500 V
Pollution degree 1
Overvoltage category II
Material group III
Rated current (40°C) 1 A
Volume resistivity ≤ 3 mΩ
Material of contact CuSn (Bronze)
Contact plating Au (gold)
Material of contact body PBT (UL 94 V-0)
Material of housing PUR
Cable data
material housing PUR
Insulation single lead PVC/ PE
Single lead structure 18 x 0,10 mm
Cable sheath Ø 5
Conductor resistance 117Ω/Km
Temperature range cable movable °C from -5
Temperature range cable movable °C to 70
Temperature range cable fixed °C from -25
Temperature range cable fixed °C to 70
Bending radius cable fixed Min. 25 mm
Bending radius cable movable Min. 50 mm

Contacts: 8, female cable connector overmoulded, unshielded, cable length 5m

Ordering number 79 1462 215 08
Connector locking system bolted
Termination molded on cable
Wire gauge (mm) 0,14 mm²
Wire gauge (AWG) 26
Cable outlet -
Cable length 5 m
Degree of protection IP67
Mechanical operation > 500 Mating cycles
Upper temperature 70 °C
Lower temperature -25 °C
Rated voltage 125 V
Rated impulse voltage 1500 V
Pollution degree 1
Overvoltage category II
Material group III
Rated current (40°C) 1 A
Volume resistivity ≤ 3 mΩ
Material of contact CuSn (Bronze)
Contact plating Au (gold)
Material of contact body PBT (UL 94 V-0)
Material of housing PUR
Cable data
material housing PUR
Insulation single lead PVC/ PE
Single lead structure 18 x 0,10 mm
Cable sheath Ø 5
Conductor resistance 117Ω/Km
Temperature range cable movable °C from -5
Temperature range cable movable °C to 70
Temperature range cable fixed °C from -25
Temperature range cable fixed °C to 70
Bending radius cable fixed Min. 25 mm
Bending radius cable movable Min. 50 mm