Available numbers of contacts
09 0036 00 03
M25 female panel mount connector, Contacts: 3, Shielding is not possible, solder, IP40
M25, series 691, Power connectors
Order number |
09 0036 00 03
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 1.50 mm² |
Wire gauge (AWG) | 16 |
Degree of protection | IP40 |
Mechanical operation | > 50 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 10 A |
Rated voltage | 250 V |
Rated impulse voltage | 2500 V |
Pollution degree | 1 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Housing material | GD-AL eloxiert |
Customs tariff number | 85369010 |
Weight (g) | 36.039 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
09 0040 00 05
M25 female panel mount connector, Contacts: 5, Shielding is not possible, solder, IP40
M25, series 691, Power connectors
Order number |
09 0040 00 05
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 1.50 mm² |
Wire gauge (AWG) | 16 |
Degree of protection | IP40 |
Mechanical operation | > 50 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 10 A |
Rated voltage | 250 V |
Rated impulse voltage | 2500 V |
Pollution degree | 1 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 5 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Ag (silver) |
Contact body material | PBT (UL 94 V-0) |
Housing material | GD-AL eloxiert |
Customs tariff number | 85369010 |
Weight (g) | 36.581 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
09 0044 00 07
M25 female panel mount connector, Contacts: 7, Shielding is not possible, solder, IP40
M25, series 691, Power connectors
Order number |
09 0044 00 07
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP40 |
Mechanical operation | > 50 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 250 V |
Rated impulse voltage | 2500 V |
Pollution degree | 1 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 8 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Ag (silver) |
Contact body material | PET (UL 94 V-0) |
Housing material | GD-AL eloxiert |
Customs tariff number | 85369010 |
Weight (g) | 35.108 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
09 0448 00 12
M25 female panel mount connector, Contacts: 12, Shielding is not possible, solder, IP40
M25, series 691, Power connectors
Order number |
09 0448 00 12
|
Connector locking system | bolted |
Termination | solder |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Degree of protection | IP40 |
Mechanical operation | > 50 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 5 A |
Rated voltage | 125 V |
Rated impulse voltage | 1500 V |
Pollution degree | 1 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 8 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Ag (silver) |
Contact body material | PET (UL 94 V-0) |
Housing material | GD-AL eloxiert |
Customs tariff number | 85369010 |
Weight (g) | 35.054 |




Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).