M16 IP67

Female angled connector

back

Series 425

Number of contacts

Variant 5

Contacts: 5, cable: 5 x 0.25mm², female angled connector

Ordering number 79 6214 200 05
Connector locking system bolted
Termination moulded on cable
Wire gauge (mm) 0,25 mm²
Wire gauge (AWG) 24
Cable outlet -
Cable length 2 m
Degree of protection IP67
Mechanical operation > 500 Mating cycles
Upper temperature 70 °C
Lower temperature -25 °C
Rated voltage 250 V
Rated impulse voltage 1500 V
Pollution degree 1
Overvoltage category I
Material group III
Rated current (40°C) 3 A
Volume resistivity ≤ 3 mΩ
Material of contact CuSn (Bronze)
Contact plating Au (gold)
Material of contact body PBT (UL 94 V-0)
Material of housing PUR
Cable data
material housing PUR
Insulation single lead PVC
Single lead structure 32 x 0,1
Cable sheath Ø 5
Bending radius cable fixed 50 mm
Bending radius cable movable 75 mm
Cable diameter 5
Variant 8 DIN

Contacts: 8 DIN, cable: 8 x 0.25mm², female angled connector

Ordering number 79 6272 200 08
Connector locking system bolted
Termination moulded on cable
Wire gauge (mm) 0,25 mm²
Wire gauge (AWG) 24
Cable outlet -
Cable length 2 m
Degree of protection IP67
Mechanical operation > 500 Mating cycles
Upper temperature 70 °C
Lower temperature -25 °C
Rated voltage 60 V
Rated impulse voltage 500 V
Pollution degree 1
Overvoltage category I
Material group III
Rated current (40°C) 3 A
Volume resistivity ≤ 3 mΩ
Material of contact CuSn (Bronze)
Contact plating Au (gold)
Material of contact body PBT (UL 94 V-0)
Material of housing PUR
Cable data
material housing PUR
Insulation single lead PVC
Single lead structure 32 x 0,1
Cable sheath Ø 5.7
Bending radius cable fixed 57 mm
Bending radius cable movable 85 mm
Cable diameter 5.7
Variant 12

Contacts: 12, cable: 12 x 0.25mm², female angled connector

Ordering number 79 6230 200 12
Connector locking system bolted
Termination moulded on cable
Wire gauge (mm) 0,25 mm²
Wire gauge (AWG) 24
Cable outlet -
Cable length 2 m
Degree of protection IP67
Mechanical operation > 500 Mating cycles
Upper temperature 70 °C
Lower temperature -25 °C
Rated voltage 60 V
Rated impulse voltage 500 V
Pollution degree 1
Overvoltage category I
Material group III
Rated current (40°C) 3 A
Volume resistivity ≤ 3 mΩ
Material of contact CuSn (Bronze)
Contact plating Au (gold)
Material of contact body PBT (UL 94 V-0)
Material of housing PUR
Cable data
material housing PUR
Insulation single lead PVC
Single lead structure 14x0,15 mm
Cable sheath Ø 7
Bending radius cable fixed 70 mm
Bending radius cable movable 105 mm
Cable diameter 7
Variant 14

Contacts: 14, cable: 8 x 0.25mm², 2 x 0.5mm², female angled connector

Ordering number 79 6252 200 14
Connector locking system bolted
Termination moulded on cable
Wire gauge (mm) 8x 0,25 mm² , 2x0,5 mm²
Wire gauge (AWG) 8x24, 2x20
Cable outlet -
Cable length 2 m
Degree of protection IP67
Mechanical operation > 500 Mating cycles
Upper temperature 70 °C
Lower temperature -25 °C
Rated voltage 60 V
Rated impulse voltage 500 V
Pollution degree 1
Overvoltage category I
Material group III
Rated current (40°C) 3 A
Volume resistivity ≤ 3 mΩ
Material of contact CuSn (Bronze)
Contact plating Au (gold)
Material of contact body PBT (UL 94 V-0)
Material of housing PUR
Cable data
material housing PUR
Insulation single lead PVC
Single lead structure 32 x 0,1
Cable sheath Ø 8
Bending radius cable fixed 80 mm
Bending radius cable movable 120 mm
Cable diameter 8