Ordering no:
Female panel mount connector, straight, 6 mm, dip-solder, UL approval
Female panel mount connector, straight, 6 mm, dip-solder, UL approval, Series 768/718
Available numbers of contacts
99 3412 281 03
M8 female panel mount connector, Contacts: 3, not shielded, dip-solder, IP67, UL
M8, series 718, Automation technology - sensors and actuators
Order number |
99 3412 281 03
|
Connector locking system | bolted |
Termination | dip-solder |
Degree of protection | IP67 |
Mechanical operation | > 100 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 4 A |
Rated voltage | 60 V |
Rated impulse voltage | 1500 V |
Pollution degree | 3 |
Overvoltage category | II |
Insulating material group | II |
Volume resistivity | ≤ 3 mΩ |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PA |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 3 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
99 3390 281 04
M8 female panel mount connector, Contacts: 4, not shielded, dip-solder, IP67, UL
M8, series 718, Automation technology - sensors and actuators
Order number |
99 3390 281 04
|
Connector locking system | bolted |
Termination | dip-solder |
Degree of protection | IP67 |
Mechanical operation | > 100 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 4 A |
Rated voltage | 60 V |
Rated impulse voltage | 1500 V |
Pollution degree | 3 |
Overvoltage category | II |
Insulating material group | II |
Volume resistivity | ≤ 3 mΩ |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PA |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 3.276 |




Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
Certificates
CAD files
Contact to customer service