M8, Female cable connector, overmoulded, screw type, M8x1, shielded, Series 718

Female cable connector, overmoulded, screw type, M8x1, shielded

Back
Ordering no:

Female cable connector, overmoulded, screw type, M8x1, shielded

Female cable connector, overmoulded, screw type, M8x1, shielded, Series 718

77 3506 0000 50003-0200

M8 female cable connector, Contacts: 3, shielded, moulded on cable, IP67, UL listed, PUR black, 3 x 0,34 mm²

M12, series 718, Automation technology - sensors and actuators

Order number
77 3506 0000 50003-0200
Old order number 79 3506 52 03
Connector locking system bolted
Termination moulded on cable
Wire gauge (mm) 0,34 mm²
Wire gauge (AWG) (22)
Cable length 2 m
Degree of protection IP67
Mechanical operation > 100 Mating cycles
Upper limit temperature 85 °C
Lower limit temperature -25 °C
Rated current (40 °C) 4 A
Rated voltage 60 V
Rated impulse voltage 1500 V
Pollution degree 3
Overvoltage category II
Insulating material group II
Volume resistivity ≤ 3 mΩ
Contact material CuZn (brass)
Contact plating Au (gold)
Contact body material PUR
Housing material PUR
Cable data
Sheath material PUR
Single-lead insulation PP
Single-lead structure 42 x 0,1
Cable diameter 4.6
Conductor resistance 60 Ω/Km
Temperature range, moving cable, °C from -25
Temperature range, moving cable, °C to 90
Temperature range, fixed cable, °C from -50
Temperature range, fixed cable, °C to 90
Bending radius, fixed cable min. 5 x D
Bending radius, moving cable min. 10 x D
Bending cycles 2 Mio.
Permitted acceleration 5 m/s²
Travel distance, horizontal 5m
Travel distance, vertical 5m
Approval 1 UL listed
UL style 1 AWM20549
Customs tariff number 85444290
Weight (g) 70
Report product error
Show more technical dataShow less technical data
77 3506 0000 50003-0500

M8 female cable connector, Contacts: 3, shielded, moulded on cable, IP67, UL listed, PUR black, 3 x 0,34 mm²

M12, series 718, Automation technology - sensors and actuators

Order number
77 3506 0000 50003-0500
Old order number 79 3506 55 03
Connector locking system bolted
Termination moulded on cable
Wire gauge (mm) 0,34 mm²
Wire gauge (AWG) (22)
Cable length 5 m
Degree of protection IP67
Mechanical operation > 100 Mating cycles
Upper limit temperature 85 °C
Lower limit temperature -25 °C
Rated current (40 °C) 4 A
Rated voltage 60 V
Rated impulse voltage 1500 V
Pollution degree 3
Overvoltage category II
Insulating material group II
Volume resistivity ≤ 3 mΩ
Contact material CuZn (brass)
Contact plating Au (gold)
Contact body material PUR
Housing material PUR
Cable data
Sheath material PUR
Single-lead insulation PP
Single-lead structure 42 x 0,1
Cable diameter 4.6
Conductor resistance 60 Ω/Km
Temperature range, moving cable, °C from -25
Temperature range, moving cable, °C to 90
Temperature range, fixed cable, °C from -50
Temperature range, fixed cable, °C to 90
Bending radius, fixed cable min. 5 x D
Bending radius, moving cable min. 10 x D
Bending cycles 2 Mio.
Permitted acceleration 5 m/s²
Travel distance, horizontal 5m
Travel distance, vertical 5m
Approval 1 UL listed
UL style 1 AWM20549
Customs tariff number 85444290
Weight (g) 70
Report product error
Show more technical dataShow less technical data
77 3506 0000 50004-0200

M8 female cable connector, Contacts: 4, shielded, moulded on cable, IP67, UL listed, PUR black, 4 x 0,25 mm²

M8, series 718, Automation technology - sensors and actuators

Order number
77 3506 0000 50004-0200
Connector locking system bolted
Termination moulded on cable
Wire gauge (mm) 0,34 mm²
Wire gauge (AWG) (22)
Cable length 2 m
Degree of protection IP67
Mechanical operation > 100 Mating cycles
Upper limit temperature 85 °C
Lower limit temperature -25 °C
Rated current (40 °C) 4 A
Rated voltage 60 V
Rated impulse voltage 1500 V
Pollution degree 3
Overvoltage category II
Insulating material group II
Volume resistivity ≤ 3 mΩ
Contact material CuZn (brass)
Contact plating Au (gold)
Contact body material PUR
Housing material PUR
Cable data
Sheath material PUR
Single-lead insulation PP
Single-lead structure 42 x 0,1
Cable diameter 4.7
Conductor resistance 60 Ω/Km
Temperature range, moving cable, °C from -25
Temperature range, moving cable, °C to 90
Temperature range, fixed cable, °C from -50
Temperature range, fixed cable, °C to 90
Bending radius, fixed cable min. 5 x D
Bending radius, moving cable min. 10 x D
Bending cycles 2 Mio.
Permitted acceleration 5 m/s²
Travel distance, horizontal 5m
Travel distance, vertical 5m
Approval 1 UL listed
UL style 1 AWM20549
Customs tariff number 85444290
Weight (g) 77
Report product error
Show more technical dataShow less technical data
77 3506 0000 50004-0500

M8 female cable connector, Contacts: 4, shielded, moulded on cable, IP67, UL listed, PUR black, 4 x 0,25 mm²

M8, series 718, Automation technology - sensors and actuators

Order number
77 3506 0000 50004-0500
Connector locking system bolted
Termination moulded on cable
Wire gauge (mm) 0,34 mm²
Wire gauge (AWG) (22)
Cable length 5 m
Degree of protection IP67
Mechanical operation > 100 Mating cycles
Upper limit temperature 85 °C
Lower limit temperature -25 °C
Rated current (40 °C) 4 A
Rated voltage 60 V
Rated impulse voltage 1500 V
Pollution degree 3
Overvoltage category II
Insulating material group II
Volume resistivity ≤ 3 mΩ
Contact material CuZn (brass)
Contact plating Au (gold)
Contact body material PUR
Housing material PUR
Cable data
Sheath material PUR
Single-lead insulation PP
Single-lead structure 42 x 0,1
Cable diameter 4.7
Conductor resistance 60 Ω/Km
Temperature range, moving cable, °C from -25
Temperature range, moving cable, °C to 90
Temperature range, fixed cable, °C from -50
Temperature range, fixed cable, °C to 90
Bending radius, fixed cable min. 5 x D
Bending radius, moving cable min. 10 x D
Bending cycles 2 Mio.
Permitted acceleration 5 m/s²
Travel distance, horizontal 5m
Travel distance, vertical 5m
Approval 1 UL listed
UL style 1 AWM20549
Customs tariff number 85444290
Weight (g) 77
Report product error
Show more technical dataShow less technical data