Ordering no:
Male angled cable connector, overmoulded, PVC grey, stainless steel thread locking, for food and beverage
Male angled cable connector, overmoulded, PVC grey, stainless steel thread locking, for food and beverage, Series 763 FOOD & BEVERAGE
Available numbers of contacts
77 3727 0000 20403-0200
M12-A male angled connector, Contacts: 3, not shielded, moulded on cable, IP69K, Standard cable, PVC grey, 3 x 0,34 mm²
M12, series 763, Automation technology - sensors and actuators
Order number |
77 3727 0000 20403-0200
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.34 mm² |
Wire gauge (AWG) | (22) |
Cable length | 2 m |
Degree of protection | IP69K |
Mechanical operation | > 100 Mating cycles |
Upper limit temperature | 105 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 4 A |
Rated voltage | 250 V |
Rated impulse voltage | 2500 V |
Pollution degree | 3 |
Overvoltage category | II |
Insulating material group | II |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PUR |
Housing material | PUR |
Cable data | |
Sheath material | PVC |
Single-lead insulation | PVC |
Single-lead structure | 42 x 0,1 |
Cable diameter | 4.5 |
Conductor resistance | 57 Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 105 |
Temperature range, fixed cable, °C from | -40 |
Temperature range, fixed cable, °C to | 105 |
Bending radius, fixed cable | min. 5 x D |
Bending radius, moving cable | min. 10 x D |
Bending cycles | 2 Mio. |
Permitted acceleration | 5 m/s² |
Travel distance, horizontal | 5 m |
Travel distance, vertical | 2 m |
Travel speed | At 5 m horizontal level up to 200 m/min. |
UL style 1 | AWM2517 |
Customs tariff number | 85444290 |
Weight (g) | 73 |


Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
CAD files
77 3727 0000 20403-0500
M12-A male angled connector, Contacts: 3, not shielded, moulded on cable, IP69K, Standard cable, PVC grey, 3 x 0,34 mm²
M12, series 763, Automation technology - sensors and actuators
Order number |
77 3727 0000 20403-0500
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.34 mm² |
Wire gauge (AWG) | (22) |
Cable length | 5 m |
Degree of protection | IP69K |
Mechanical operation | > 100 Mating cycles |
Upper limit temperature | 105 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 4 A |
Rated voltage | 250 V |
Rated impulse voltage | 2500 V |
Pollution degree | 3 |
Overvoltage category | II |
Insulating material group | II |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PUR |
Housing material | PUR |
Cable data | |
Sheath material | PVC |
Single-lead insulation | PVC |
Single-lead structure | 42 x 0,1 |
Cable diameter | 4.5 |
Conductor resistance | 57 Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 105 |
Temperature range, fixed cable, °C from | -40 |
Temperature range, fixed cable, °C to | 105 |
Bending radius, fixed cable | min. 5 x D |
Bending radius, moving cable | min. 10 x D |
Bending cycles | 2 Mio. |
Permitted acceleration | 5 m/s² |
Travel distance, horizontal | 5 m |
Travel distance, vertical | 2 m |
Travel speed | At 5 m horizontal level up to 200 m/min. |
UL style 1 | AWM2517 |
Customs tariff number | 85444290 |
Weight (g) | 73 |


Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
CAD files
77 3727 0000 20404-0200
M12-A male angled connector, Contacts: 4, not shielded, moulded on cable, IP69K, Standard cable, PVC grey, 4 x 0,34 mm²
M12, series 763, Automation technology - sensors and actuators
Order number |
77 3727 0000 20404-0200
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.34 mm² |
Wire gauge (AWG) | (22) |
Cable length | 2 m |
Degree of protection | IP69K |
Mechanical operation | > 100 Mating cycles |
Upper limit temperature | 105 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 4 A |
Rated voltage | 250 V |
Rated impulse voltage | 2500 V |
Pollution degree | 3 |
Overvoltage category | II |
Insulating material group | II |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PUR |
Housing material | PUR |
Cable data | |
Sheath material | PVC |
Single-lead insulation | PVC |
Single-lead structure | 42 x 0,1 |
Cable diameter | 4.8 |
Conductor resistance | 57 Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 105 |
Temperature range, fixed cable, °C from | -40 |
Temperature range, fixed cable, °C to | 105 |
Bending radius, fixed cable | min. 5 x D |
Bending radius, moving cable | min. 10 x D |
Bending cycles | 2 Mio. |
Permitted acceleration | 5 m/s² |
Travel distance, horizontal | 5 m |
Travel distance, vertical | 2 m |
Travel speed | At 5 m horizontal level up to 200 m/min. |
UL style 1 | AWM2517 |
Customs tariff number | 85444290 |
Weight (g) | 85 |



Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
77 3727 0000 20404-0500
M12-A male angled connector, Contacts: 4, not shielded, moulded on cable, IP69K, Standard cable, PVC grey, 4 x 0,34 mm²
M12, series 763, Automation technology - sensors and actuators
Order number |
77 3727 0000 20404-0500
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.34 mm² |
Wire gauge (AWG) | (22) |
Cable length | 5 m |
Degree of protection | IP69K |
Mechanical operation | > 100 Mating cycles |
Upper limit temperature | 105 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 4 A |
Rated voltage | 250 V |
Rated impulse voltage | 2500 V |
Pollution degree | 3 |
Overvoltage category | II |
Insulating material group | II |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PUR |
Housing material | PUR |
Cable data | |
Sheath material | PVC |
Single-lead insulation | PVC |
Single-lead structure | 42 x 0,1 |
Cable diameter | 4.8 |
Conductor resistance | 57 Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 105 |
Temperature range, fixed cable, °C from | -40 |
Temperature range, fixed cable, °C to | 105 |
Bending radius, fixed cable | min. 5 x D |
Bending radius, moving cable | min. 10 x D |
Bending cycles | 2 Mio. |
Permitted acceleration | 5 m/s² |
Travel distance, horizontal | 5 m |
Travel distance, vertical | 2 m |
Travel speed | At 5 m horizontal level up to 200 m/min. |
UL style 1 | AWM2517 |
Customs tariff number | 85444290 |
Weight (g) | 85 |



Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
77 3727 0000 20405-0200
M12-A male angled connector, Contacts: 5, not shielded, moulded on cable, IP69K, Standard cable, PVC grey, 5 x 0,34 mm²
M12, series 763, Automation technology - sensors and actuators
Order number |
77 3727 0000 20405-0200
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.34 mm² |
Wire gauge (AWG) | (22) |
Cable length | 2 m |
Degree of protection | IP69K |
Mechanical operation | > 100 Mating cycles |
Upper limit temperature | 105 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 4 A |
Rated voltage | 60 V |
Rated impulse voltage | 1500 V |
Pollution degree | 3 |
Overvoltage category | II |
Insulating material group | II |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PUR |
Housing material | PUR |
Cable data | |
Sheath material | PVC |
Single-lead insulation | PVC |
Single-lead structure | 42 x 0,1 |
Cable diameter | 4.8 |
Conductor resistance | 57 Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 105 |
Temperature range, fixed cable, °C from | -40 |
Temperature range, fixed cable, °C to | 105 |
Bending radius, fixed cable | min. 5 x D |
Bending radius, moving cable | min. 10 x D |
Bending cycles | 2 Mio. |
Permitted acceleration | 5 m/s² |
Travel distance, horizontal | 5 m |
Travel distance, vertical | 2 m |
Travel speed | At 5 m horizontal level up to 200 m/min. |
UL style 1 | AWM2517 |
Customs tariff number | 85444290 |
Weight (g) | 95 |



Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
77 3727 0000 20405-0500
M12-A male angled connector, Contacts: 5, not shielded, moulded on cable, IP69K, Standard cable, PVC grey, 5 x 0,34 mm²
M12, series 763, Automation technology - sensors and actuators
Order number |
77 3727 0000 20405-0500
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.34 mm² |
Wire gauge (AWG) | (22) |
Cable length | 5 m |
Degree of protection | IP69K |
Mechanical operation | > 100 Mating cycles |
Upper limit temperature | 105 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 4 A |
Rated voltage | 60 V |
Rated impulse voltage | 1500 V |
Pollution degree | 3 |
Overvoltage category | II |
Insulating material group | II |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PUR |
Housing material | PUR |
Cable data | |
Sheath material | PVC |
Single-lead insulation | PVC |
Single-lead structure | 42 x 0,1 |
Cable diameter | 4.8 |
Conductor resistance | 57 Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 105 |
Temperature range, fixed cable, °C from | -40 |
Temperature range, fixed cable, °C to | 105 |
Bending radius, fixed cable | min. 5 x D |
Bending radius, moving cable | min. 10 x D |
Bending cycles | 2 Mio. |
Permitted acceleration | 5 m/s² |
Travel distance, horizontal | 5 m |
Travel distance, vertical | 2 m |
Travel speed | At 5 m horizontal level up to 200 m/min. |
UL style 1 | AWM2517 |
Customs tariff number | 85444290 |
Weight (g) | 95 |



Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
77 3727 0000 20908-0200
M12-A male angled connector, Contacts: 8, not shielded, moulded on cable, IP69K, Standard cable, PVC grey, 8 x 0,25 mm²
M12, series 763, Automation technology - sensors and actuators
Order number |
77 3727 0000 20908-0200
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | (24) |
Cable length | 2 m |
Degree of protection | IP69K |
Mechanical operation | > 100 Mating cycles |
Upper limit temperature | 105 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 2 A |
Rated voltage | 30 V |
Rated impulse voltage | 800 V |
Pollution degree | 3 |
Overvoltage category | II |
Insulating material group | II |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PUR |
Housing material | PUR |
Cable data | |
Sheath material | PVC |
Single-lead insulation | PVC |
Single-lead structure | 32 x 0,1 |
Cable diameter | 6 |
Conductor resistance | <79Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 105 |
Temperature range, fixed cable, °C from | -40 |
Temperature range, fixed cable, °C to | 105 |
Bending radius, fixed cable | min. 5 x D |
Bending radius, moving cable | min. 10 x D |
Bending cycles | 2 Mio. |
Permitted acceleration | 5 m/s² |
Travel distance, horizontal | 5 m |
Travel distance, vertical | 2 m |
Travel speed | At 5 m horizontal level up to 200 m/min. |
UL style 1 | AWM2517 |
Customs tariff number | 85444290 |
Weight (g) | 126 |



Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
77 3727 0000 20908-0500
M12-A male angled connector, Contacts: 8, not shielded, moulded on cable, IP69K, Standard cable, PVC grey, 8 x 0,25 mm²
M12, series 763, Automation technology - sensors and actuators
Order number |
77 3727 0000 20908-0500
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | (24) |
Cable length | 5 m |
Degree of protection | IP69K |
Mechanical operation | > 100 Mating cycles |
Upper limit temperature | 105 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 2 A |
Rated voltage | 30 V |
Rated impulse voltage | 800 V |
Pollution degree | 3 |
Overvoltage category | II |
Insulating material group | II |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PUR |
Housing material | PUR |
Cable data | |
Sheath material | PVC |
Single-lead insulation | PVC |
Single-lead structure | 32 x 0,1 |
Cable diameter | 6 |
Conductor resistance | <79Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 105 |
Temperature range, fixed cable, °C from | -40 |
Temperature range, fixed cable, °C to | 105 |
Bending radius, fixed cable | min. 5 x D |
Bending radius, moving cable | min. 10 x D |
Bending cycles | 2 Mio. |
Permitted acceleration | 5 m/s² |
Travel distance, horizontal | 5 m |
Travel distance, vertical | 2 m |
Travel speed | At 5 m horizontal level up to 200 m/min. |
UL style 1 | AWM2517 |
Customs tariff number | 85444290 |
Weight (g) | 126 |



Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
77 3727 0000 20912-0200
M12-A male angled connector, Contacts: 12, not shielded, moulded on cable, IP69K, Standard cable, PVC grey, 12 x 0,25 mm²
M12, series 763, Automation technology - sensors and actuators
Order number |
77 3727 0000 20912-0200
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | (24) |
Cable length | 2 m |
Degree of protection | IP69K |
Mechanical operation | > 100 Mating cycles |
Upper limit temperature | 105 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 1,5 A |
Rated voltage | 30 V |
Rated impulse voltage | 800 V |
Pollution degree | 3 |
Overvoltage category | II |
Insulating material group | II |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PUR |
Housing material | PUR |
Cable data | |
Sheath material | PVC |
Single-lead insulation | PVC |
Single-lead structure | 32 x 0,1 |
Cable diameter | 6.6 |
Conductor resistance | 75 Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 105 |
Temperature range, fixed cable, °C from | -40 |
Temperature range, fixed cable, °C to | 105 |
Bending radius, fixed cable | min. 5 x D |
Bending radius, moving cable | min. 10 x D |
Bending cycles | 2 Mio. |
Permitted acceleration | 5 m/s² |
Travel distance, horizontal | 5 m |
Travel distance, vertical | 2 m |
Travel speed | At 5 m horizontal level up to 200 m/min. |
UL style 1 | AWM2517 |
Customs tariff number | 85444290 |
Weight (g) | 155 |



Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
77 3727 0000 20912-0500
M12-A male angled connector, Contacts: 12, not shielded, moulded on cable, IP69K, Standard cable, PVC grey, 12 x 0,25 mm²
M12, series 763, Automation technology - sensors and actuators
Order number |
77 3727 0000 20912-0500
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.25 mm² |
Wire gauge (AWG) | (24) |
Cable length | 5 m |
Degree of protection | IP69K |
Mechanical operation | > 100 Mating cycles |
Upper limit temperature | 105 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 1,5 A |
Rated voltage | 30 V |
Rated impulse voltage | 800 V |
Pollution degree | 3 |
Overvoltage category | II |
Insulating material group | II |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PUR |
Housing material | PUR |
Cable data | |
Sheath material | PVC |
Single-lead insulation | PVC |
Single-lead structure | 32 x 0,1 |
Cable diameter | 6.6 |
Conductor resistance | 75 Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 105 |
Temperature range, fixed cable, °C from | -40 |
Temperature range, fixed cable, °C to | 105 |
Bending radius, fixed cable | min. 5 x D |
Bending radius, moving cable | min. 10 x D |
Bending cycles | 2 Mio. |
Permitted acceleration | 5 m/s² |
Travel distance, horizontal | 5 m |
Travel distance, vertical | 2 m |
Travel speed | At 5 m horizontal level up to 200 m/min. |
UL style 1 | AWM2517 |
Customs tariff number | 85444290 |
Weight (g) | 155 |



Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
Contact to customer service
Do you have any questions regarding our products or do you wish an individual offer?