Ordering no:
Female cable connector, stainless steel threaded lock, screw terminal connection, gold plated contacts, UL approval
Female cable connector, stainless steel threaded lock, screw terminal connection, gold plated contacts, UL approval, Series 713
Available numbers of contacts
99 0430 82 04
M12-A female cable connector, Contacts: 4, 4,0 - 6,0 mm, not shielded, screw clamp, IP67, UL
M12, series 713, Automation technology - sensors and actuators
Order number |
99 0430 82 04
|
Connector locking system | bolted |
Termination | screw clamp |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | (18) |
Cable outlet | 4,0 - 6,0 mm |
Degree of protection | IP67 |
Mechanical operation | > 100 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 4 A (3 A UL) |
Rated voltage | 250 V |
Rated impulse voltage | 2500 V |
Pollution degree | 3 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | >10⁸Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PA |
Housing material | PA |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 24.393 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
99 0430 282 04
M12-A female cable connector, Contacts: 4, 6,0 - 8,0 mm, not shielded, screw clamp, IP67, UL
M12, series 713, Automation technology - sensors and actuators
Order number |
99 0430 282 04
|
Connector locking system | bolted |
Termination | screw clamp |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | (18) |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP67 |
Mechanical operation | > 100 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 4 A (3 A UL) |
Rated voltage | 250 V |
Rated impulse voltage | 2500 V |
Pollution degree | 3 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | >10⁸Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PA |
Housing material | PA |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 25.896 |





Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- To prevent the connector being opened unintentionally when used in electrical circuits containing hazardous life parts, the thread between the housing and the connector head must be secured using a suitable cyanoacrylate adhesive. This does not apply to connectors used in SELV and PELV circuits according to IEC 61140 (EN 61140, VDE 0140-1).
- Connectors used in electrical circuits containing hazardous life parts must only be assembled and used by or under the supervision of persons with the requisite electrotechnical training, taking the applicable regulations and standards into account.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
99 0436 82 05
M12-A female cable connector, Contacts: 5, 4,0 - 6,0 mm, not shielded, screw clamp, IP67, UL
M12, series 713, Automation technology - sensors and actuators
Order number |
99 0436 82 05
|
Connector locking system | bolted |
Termination | screw clamp |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | (18) |
Cable outlet | 4,0 - 6,0 mm |
Degree of protection | IP67 |
Mechanical operation | > 100 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 4 A (3 A UL) |
Rated voltage | 60 V |
Rated impulse voltage | 1500 V |
Pollution degree | 3 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | >10⁸Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PA |
Housing material | PA |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 25.457 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
99 0436 282 05
M12-A female cable connector, Contacts: 5, 6,0 - 8,0 mm, not shielded, screw clamp, IP67, UL
M12, series 713, Automation technology - sensors and actuators
Order number |
99 0436 282 05
|
Connector locking system | bolted |
Termination | screw clamp |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | (18) |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP67 |
Mechanical operation | > 100 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 4 A (3 A UL) |
Rated voltage | 60 V |
Rated impulse voltage | 1500 V |
Pollution degree | 3 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | >10⁸Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PA |
Housing material | PA |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 26.96 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
99 0486 282 08
M12-A female cable connector, Contacts: 8, 6,0 - 8,0 mm, not shielded, screw clamp, IP67, UL
M12, series 713, Automation technology - sensors and actuators
Order number |
99 0486 282 08
|
Connector locking system | bolted |
Termination | screw clamp |
Wire gauge (mm) | 0.50 mm² |
Wire gauge (AWG) | (20) |
Cable outlet | 6,0 - 8,0 mm |
Degree of protection | IP67 |
Mechanical operation | > 100 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -40 °C |
Rated current (40 °C) | 1,5 A (2 A UL) |
Rated voltage | 30 V |
Rated impulse voltage | 800 V |
Pollution degree | 3 |
Overvoltage category | II |
Insulating material group | III |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | >10⁸Ω |
Contact material | CuSn (bronze) |
Contact plating | Au (gold) |
Contact body material | PA |
Housing material | PA |
Approval 1 | UL |
Customs tariff number | 85369010 |
Weight (g) | 28.013 |





Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
Contact to customer service
Do you have any questions regarding our products or do you wish an individual offer?