M12-A, Cable plug connector, overmoulded, PUR, Series 763

Cable plug connector, overmoulded, PUR

Back
Ordering no:

Cable plug connector, overmoulded, PUR

Cable plug connector, overmoulded, PUR, Series 763

77 3429 0000 50003-0200

M12-A cable connector, Contacts: 3, not shielded, moulded on cable, IP69K, UL listed, PUR black, 3 x 0,34 mm²

M12, series 763, Automation technology - sensors and actuators

Order number
77 3429 0000 50003-0200
Old order number:
79 3429 32 04
Connector locking system bolted
Termination moulded on cable
Wire gauge (mm) 0,34 mm²
Wire gauge (AWG) (22)
Cable length 2 m
Degree of protection IP69K
Mechanical operation > 100 Mating cycles
Upper limit temperature 90 °C
Lower limit temperature -25 °C
Rated current (40 °C) 4 A
Rated voltage 250 V
Rated impulse voltage 2500 V
Pollution degree 3
Overvoltage category II
Insulating material group II
Volume resistivity ≤ 3 mΩ
Insulation resistance ≥ 10¹⁰Ω
Contact material CuZn (brass)
Contact plating Au (gold)
Contact body material PUR
Housing material PUR
Cable data
Sheath material PUR
Single-lead insulation PP
Single-lead structure 42 x 0,1
Cable diameter 4.3
Conductor resistance 60 Ω/Km
Temperature range, moving cable, °C from -25
Temperature range, moving cable, °C to 90
Temperature range, fixed cable, °C from -50
Temperature range, fixed cable, °C to 90
Bending radius, fixed cable min. 5 x D
Bending radius, moving cable min. 10 x D
Bending cycles 5 Mio.
Permitted acceleration 5 m/s²
Travel distance, horizontal 5 m
Travel distance, vertical 5 m
Approval 1 UL listed
UL style 1 AWM20549
Customs tariff number 85444290
Weight (g) 136
Report product error
Show more technical dataShow less technical data
77 3429 0000 50003-0500

M12-A cable connector, Contacts: 3, not shielded, moulded on cable, IP69K, UL listed, PUR black, 3 x 0,34 mm²

M12, series 763, Automation technology - sensors and actuators

Order number
77 3429 0000 50003-0500
Old order number:
79 3429 35 04
Connector locking system bolted
Termination moulded on cable
Wire gauge (mm) 0,34 mm²
Wire gauge (AWG) (22)
Cable length 5 m
Degree of protection IP69K
Mechanical operation > 100 Mating cycles
Upper limit temperature 90 °C
Lower limit temperature -25 °C
Rated current (40 °C) 4 A
Rated voltage 250 V
Rated impulse voltage 2500 V
Pollution degree 3
Overvoltage category II
Insulating material group II
Volume resistivity ≤ 3 mΩ
Insulation resistance ≥ 10¹⁰Ω
Contact material CuZn (brass)
Contact plating Au (gold)
Contact body material PUR
Housing material PUR
Cable data
Sheath material PUR
Single-lead insulation PP
Single-lead structure 42 x 0,1
Cable diameter 4.3
Conductor resistance 60 Ω/Km
Temperature range, moving cable, °C from -25
Temperature range, moving cable, °C to 90
Temperature range, fixed cable, °C from -50
Temperature range, fixed cable, °C to 90
Bending radius, fixed cable min. 5 x D
Bending radius, moving cable min. 10 x D
Bending cycles 5 Mio.
Permitted acceleration 5 m/s²
Travel distance, horizontal 5 m
Travel distance, vertical 5 m
Approval 1 UL listed
UL style 1 AWM20549
Customs tariff number 85444290
Weight (g) 136
Report product error
Show more technical dataShow less technical data
77 3429 0000 50004-0200

M12-A cable connector, Contacts: 4, not shielded, moulded on cable, IP69K, UL listed, PUR black, 4 x 0,34 mm²

M12, series 763, Automation technology - sensors and actuators

Order number
77 3429 0000 50004-0200
Old order number:
79 3429 33 04
Connector locking system bolted
Termination moulded on cable
Wire gauge (mm) 0,34 mm²
Wire gauge (AWG) (22)
Cable length 2 m
Degree of protection IP69K
Mechanical operation > 100 Mating cycles
Upper limit temperature 90 °C
Lower limit temperature -25 °C
Rated current (40 °C) 4 A
Rated voltage 250 V
Rated impulse voltage 2500 V
Pollution degree 3
Overvoltage category II
Insulating material group II
Volume resistivity ≤ 3 mΩ
Insulation resistance ≥ 10¹⁰Ω
Contact material CuZn (brass)
Contact plating Au (gold)
Contact body material PUR
Housing material PUR
Cable data
Sheath material PUR
Single-lead insulation PP
Single-lead structure 42 x 0,1
Cable diameter 4.7
Conductor resistance 60 Ω/Km
Temperature range, moving cable, °C from -25
Temperature range, moving cable, °C to 90
Temperature range, fixed cable, °C from -50
Temperature range, fixed cable, °C to 90
Bending radius, fixed cable min. 5 x D
Bending radius, moving cable min. 10 x D
Bending cycles 5 Mio.
Permitted acceleration 5 m/s²
Travel distance, horizontal 5 m
Travel distance, vertical 5 m
Approval 1 UL listed
UL style 1 AWM20549
Customs tariff number 85444290
Weight (g) 161.156
Report product error
Show more technical dataShow less technical data
77 3429 0000 50004-0500

M12-A cable connector, Contacts: 4, not shielded, moulded on cable, IP69K, UL listed, PUR black, 4 x 0,34 mm²

M12, series 763, Automation technology - sensors and actuators

Order number
77 3429 0000 50004-0500
Old order number:
79 3429 37 04
Connector locking system bolted
Termination moulded on cable
Wire gauge (mm) 0,34 mm²
Wire gauge (AWG) (22)
Cable length 5 m
Degree of protection IP69K
Mechanical operation > 100 Mating cycles
Upper limit temperature 90 °C
Lower limit temperature -25 °C
Rated current (40 °C) 4 A
Rated voltage 250 V
Rated impulse voltage 2500 V
Pollution degree 3
Overvoltage category II
Insulating material group II
Volume resistivity ≤ 3 mΩ
Insulation resistance ≥ 10¹⁰Ω
Contact material CuZn (brass)
Contact plating Au (gold)
Contact body material PUR
Housing material PUR
Cable data
Sheath material PUR
Single-lead insulation PP
Single-lead structure 42 x 0,1
Cable diameter 4.7
Conductor resistance 60 Ω/Km
Temperature range, moving cable, °C from -25
Temperature range, moving cable, °C to 90
Temperature range, fixed cable, °C from -50
Temperature range, fixed cable, °C to 90
Bending radius, fixed cable min. 5 x D
Bending radius, moving cable min. 10 x D
Bending cycles 5 Mio.
Permitted acceleration 5 m/s²
Travel distance, horizontal 5 m
Travel distance, vertical 5 m
Approval 1 UL listed
UL style 1 AWM20549
Customs tariff number 85444290
Weight (g) 161.156
Report product error
Show more technical dataShow less technical data
77 3429 0000 50005-0200

M12-A cable connector, Contacts: 5, not shielded, moulded on cable, IP69K, UL listed, PUR black, 5 x 0,34 mm²

M12, series 763, Automation technology - sensors and actuators

Order number
77 3429 0000 50005-0200
Old order number:
79 3439 32 05
Connector locking system bolted
Termination moulded on cable
Wire gauge (mm) 0,34 mm²
Wire gauge (AWG) (22)
Cable length 2 m
Degree of protection IP69K
Mechanical operation > 100 Mating cycles
Upper limit temperature 90 °C
Lower limit temperature -25 °C
Rated current (40 °C) 4 A
Rated voltage 60 V
Rated impulse voltage 1500 V
Pollution degree 3
Overvoltage category II
Insulating material group II
Volume resistivity ≤ 3 mΩ
Insulation resistance ≥ 10¹⁰Ω
Contact material CuZn (brass)
Contact plating Au (gold)
Contact body material PUR
Housing material PUR
Cable data
Sheath material PUR
Single-lead insulation PP
Single-lead structure 42 x 0,1
Cable diameter 4.7
Conductor resistance 60 Ω/Km (20°C)
Temperature range, moving cable, °C from -25
Temperature range, moving cable, °C to 90
Temperature range, fixed cable, °C from -50
Temperature range, fixed cable, °C to 90
Bending radius, fixed cable min. 5 x D
Bending radius, moving cable min. 10 x D
Bending cycles 5 Mio.
Permitted acceleration 5 m/s²
Travel distance, horizontal 5 m
Travel distance, vertical 2 m
Approval 1 UL listed
UL style 1 AWM20549
Customs tariff number 85444290
Weight (g) 83
Report product error
Show more technical dataShow less technical data
77 3429 0000 50005-0500

M12-A cable connector, Contacts: 5, not shielded, moulded on cable, IP69K, UL listed, PUR black, 5 x 0,34 mm²

M12, series 763, Automation technology - sensors and actuators

Order number
77 3429 0000 50005-0500
Old order number:
79 3439 35 05
Connector locking system bolted
Termination moulded on cable
Wire gauge (mm) 0,34 mm²
Wire gauge (AWG) (22)
Cable length 5 m
Degree of protection IP69K
Mechanical operation > 100 Mating cycles
Upper limit temperature 90 °C
Lower limit temperature -25 °C
Rated current (40 °C) 4 A
Rated voltage 60 V
Rated impulse voltage 1500 V
Pollution degree 3
Overvoltage category II
Insulating material group II
Volume resistivity ≤ 3 mΩ
Insulation resistance ≥ 10¹⁰Ω
Contact material CuZn (brass)
Contact plating Au (gold)
Contact body material PUR
Housing material PUR
Cable data
Sheath material PUR
Single-lead insulation PP
Single-lead structure 42 x 0,1
Cable diameter 4.7
Conductor resistance 60 Ω/Km (20°C)
Temperature range, moving cable, °C from -25
Temperature range, moving cable, °C to 90
Temperature range, fixed cable, °C from -50
Temperature range, fixed cable, °C to 90
Bending radius, fixed cable min. 5 x D
Bending radius, moving cable min. 10 x D
Bending cycles 5 Mio.
Permitted acceleration 5 m/s²
Travel distance, horizontal 5 m
Travel distance, vertical 2 m
Approval 1 UL listed
UL style 1 AWM20549
Customs tariff number 85444290
Weight (g) 83
Report product error
Show more technical dataShow less technical data
77 3429 0000 50708-0200

M12-A cable connector, Contacts: 8, not shielded, moulded on cable, IP69K, UL listed, PUR black, 8 x 0,25 mm²

M12, series 763, Automation technology - sensors and actuators

Order number
77 3429 0000 50708-0200
Connector locking system bolted
Termination moulded on cable
Wire gauge (mm) 0,25 mm²
Wire gauge (AWG) (24)
Cable length 2 m
Degree of protection IP69K
Mechanical operation > 100 Mating cycles
Upper limit temperature 90 °C
Lower limit temperature -25 °C
Rated current (40 °C) 2 A
Rated voltage 30 V
Rated impulse voltage 800 V
Pollution degree 3
Overvoltage category II
Insulating material group II
Volume resistivity ≤ 3 mΩ
Insulation resistance ≥ 10¹⁰Ω
Contact material CuZn (brass)
Contact plating Au (gold)
Contact body material PUR
Housing material PUR
Cable data
Sheath material PUR
Single-lead insulation PP
Single-lead structure 32 x 0,1
Cable diameter 6
Conductor resistance <79Ω/Km
Temperature range, moving cable, °C from -25
Temperature range, moving cable, °C to 90
Temperature range, fixed cable, °C from -50
Temperature range, fixed cable, °C to 90
Bending radius, fixed cable min. 5 x D
Bending radius, moving cable min. 10 x D
Bending cycles 2 Mio.
Permitted acceleration 5 m/s²
Travel distance, horizontal 5 m
Travel distance, vertical 2 m
Approval 1 UL listed
UL style 1 AWM20549
Customs tariff number 85444290
Weight (g) 111
Report product error
Show more technical dataShow less technical data
77 3429 0000 50708-0500

M12-A cable connector, Contacts: 8, not shielded, moulded on cable, IP69K, UL listed, PUR black, 8 x 0,25 mm²

M12, series 763, Automation technology - sensors and actuators

Order number
77 3429 0000 50708-0500
Connector locking system bolted
Termination moulded on cable
Wire gauge (mm) 0,25 mm²
Wire gauge (AWG) (24)
Cable length 5 m
Degree of protection IP69K
Mechanical operation > 100 Mating cycles
Upper limit temperature 90 °C
Lower limit temperature -25 °C
Rated current (40 °C) 2 A
Rated voltage 30 V
Rated impulse voltage 800 V
Pollution degree 3
Overvoltage category II
Insulating material group II
Volume resistivity ≤ 3 mΩ
Insulation resistance ≥ 10¹⁰Ω
Contact material CuZn (brass)
Contact plating Au (gold)
Contact body material PUR
Housing material PUR
Cable data
Sheath material PUR
Single-lead insulation PP
Single-lead structure 32 x 0,1
Cable diameter 6
Conductor resistance <79Ω/Km
Temperature range, moving cable, °C from -25
Temperature range, moving cable, °C to 90
Temperature range, fixed cable, °C from -50
Temperature range, fixed cable, °C to 90
Bending radius, fixed cable min. 5 x D
Bending radius, moving cable min. 10 x D
Bending cycles 2 Mio.
Permitted acceleration 5 m/s²
Travel distance, horizontal 5 m
Travel distance, vertical 2 m
Approval 1 UL listed
UL style 1 AWM20549
Customs tariff number 85444290
Weight (g) 111
Report product error
Show more technical dataShow less technical data
77 3429 0000 50608-0200

M12-A cable connector, Contacts: 8, shielded, shield on pin 8, moulded on cable, IP69K, UL listed, Shielded cable, PUR black, 8 x 0,25 mm²

M12, series 763, Automation technology - sensors and actuators

Order number
77 3429 0000 50608-0200
Old order number:
79 3479 32 08
Connector locking system bolted
Termination moulded on cable
Wire gauge (mm) 0,25 mm²
Wire gauge (AWG) (24)
Cable length 2 m
Degree of protection IP69K
Mechanical operation > 100 Mating cycles
Upper limit temperature 90 °C
Lower limit temperature -25 °C
Rated current (40 °C) 2 A
Rated voltage 30 V
Rated impulse voltage 800 V
Pollution degree 3
Overvoltage category II
Insulating material group II
Volume resistivity ≤ 3 mΩ
Insulation resistance ≥ 10¹⁰Ω
Contact material CuZn (brass)
Contact plating Au (gold)
Contact body material PUR
Housing material PUR
Cable data
Sheath material PUR
Single-lead insulation PP
Single-lead structure 32 x 0,1
Cable diameter 5.7
Conductor resistance 79 Ω/Km
Temperature range, moving cable, °C from -25
Temperature range, moving cable, °C to 90
Temperature range, fixed cable, °C from -50
Temperature range, fixed cable, °C to 80
Bending radius, fixed cable min. 5 x D
Bending radius, moving cable min. 10 x D
Bending cycles 2 Mio.
Permitted acceleration 5 m/s²
Travel distance, horizontal 5 m
Travel distance, vertical 2 m
Approval 1 UL listed
Customs tariff number 85444290
Weight (g) 120
Report product error
Show more technical dataShow less technical data
77 3429 0000 50608-0500

M12-A cable connector, Contacts: 8, shielded, shield on pin 8, moulded on cable, IP69K, UL listed, Shielded cable, PUR black, 8 x 0,25 mm²

M12, series 763, Automation technology - sensors and actuators

Order number
77 3429 0000 50608-0500
Old order number:
79 3479 35 08
Connector locking system bolted
Termination moulded on cable
Wire gauge (mm) 0,25 mm²
Wire gauge (AWG) (24)
Cable length 5 m
Degree of protection IP69K
Mechanical operation > 100 Mating cycles
Upper limit temperature 90 °C
Lower limit temperature -25 °C
Rated current (40 °C) 2 A
Rated voltage 30 V
Rated impulse voltage 800 V
Pollution degree 3
Overvoltage category II
Insulating material group II
Volume resistivity ≤ 3 mΩ
Insulation resistance ≥ 10¹⁰Ω
Contact material CuZn (brass)
Contact plating Au (gold)
Contact body material PUR
Housing material PUR
Cable data
Sheath material PUR
Single-lead insulation PP
Single-lead structure 32 x 0,1
Cable diameter 5.7
Conductor resistance 79 Ω/Km
Temperature range, moving cable, °C from -25
Temperature range, moving cable, °C to 90
Temperature range, fixed cable, °C from -50
Temperature range, fixed cable, °C to 80
Bending radius, fixed cable min. 5 x D
Bending radius, moving cable min. 10 x D
Bending cycles 2 Mio.
Permitted acceleration 5 m/s²
Travel distance, horizontal 5 m
Travel distance, vertical 2 m
Travel speed At 5 m horizontal level up to 200 m/min.
Approval 1 UL listed
Customs tariff number 85444290
Weight (g) 120
Report product error
Show more technical dataShow less technical data
77 3429 0000 50712-0200

M12-A cable connector, Contacts: 12, not shielded, moulded on cable, IP69K, UL listed, PUR black, 12 x 0,25 mm²

M12, series 763, Automation technology - sensors and actuators

Order number
77 3429 0000 50712-0200
Connector locking system bolted
Termination moulded on cable
Wire gauge (mm) 0,25 mm²
Wire gauge (AWG) (24)
Cable length 2 m
Degree of protection IP69K
Mechanical operation > 100 Mating cycles
Upper limit temperature 90 °C
Lower limit temperature -25 °C
Rated current (40 °C) 1,5 A
Rated voltage 30 V
Rated impulse voltage 800 V
Pollution degree 3
Overvoltage category II
Insulating material group II
Volume resistivity ≤ 3 mΩ
Insulation resistance ≥ 10¹⁰Ω
Contact material CuZn (brass)
Contact plating Au (gold)
Contact body material PUR
Housing material PUR
Cable data
Sheath material PUR
Single-lead insulation PP
Single-lead structure 32 x 0,1
Cable diameter 6.5
Conductor resistance 79 Ω/Km
Temperature range, moving cable, °C from -25
Temperature range, moving cable, °C to 90
Temperature range, fixed cable, °C from -50
Temperature range, fixed cable, °C to 90
Bending radius, fixed cable min. 5 x D
Bending radius, moving cable min. 10 x D
Bending cycles 2 Mio.
Permitted acceleration 5 m/s²
Travel distance, horizontal 5 m
Travel distance, vertical 2 m
Approval 1 UL listed
UL style 1 AWM20549
Customs tariff number 85444290
Weight (g) 134
Report product error
Show more technical dataShow less technical data
77 3429 0000 50712-0500

M12-A cable connector, Contacts: 12, not shielded, moulded on cable, IP69K, UL listed, PUR black, 12 x 0,25 mm²

M12, series 763, Automation technology - sensors and actuators

Order number
77 3429 0000 50712-0500
Connector locking system bolted
Termination moulded on cable
Wire gauge (mm) 0,25 mm²
Wire gauge (AWG) (24)
Cable length 5 m
Degree of protection IP69K
Mechanical operation > 100 Mating cycles
Upper limit temperature 90 °C
Lower limit temperature -25 °C
Rated current (40 °C) 1,5 A
Rated voltage 30 V
Rated impulse voltage 800 V
Pollution degree 3
Overvoltage category II
Insulating material group II
Volume resistivity ≤ 3 mΩ
Insulation resistance ≥ 10¹⁰Ω
Contact material CuZn (brass)
Contact plating Au (gold)
Contact body material PUR
Housing material PUR
Cable data
Sheath material PUR
Single-lead insulation PP
Single-lead structure 32 x 0,1
Cable diameter 6.5
Conductor resistance 79 Ω/Km
Temperature range, moving cable, °C from -25
Temperature range, moving cable, °C to 90
Temperature range, fixed cable, °C from -50
Temperature range, fixed cable, °C to 90
Bending radius, fixed cable min. 5 x D
Bending radius, moving cable min. 10 x D
Bending cycles 2 Mio.
Permitted acceleration 5 m/s²
Travel distance, horizontal 5 m
Travel distance, vertical 2 m
Approval 1 UL listed
UL style 1 AWM20549
Customs tariff number 85444290
Weight (g) 134
Report product error
Show more technical dataShow less technical data
Contact to customer service
Do you have any questions regarding our products or do you wish an individual offer?