Available numbers of contacts
77 4429 0000 20003-0200
M12-B cable connector, Contacts: 3, not shielded, moulded on cable, IP68, UL listed, PVC black, 3 x 0,34 mm²
M12, series 766, Automation technology - data transmission and power supply
Order number |
77 4429 0000 20003-0200
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.34 mm² |
Wire gauge (AWG) | (22) |
Cable length | 2 m |
Degree of protection | IP68 |
Mechanical operation | > 100 Mating cycles |
Upper limit temperature | 90 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 4 A |
Rated voltage | 250 V |
Rated impulse voltage | 2500 V |
Pollution degree | 3 |
Overvoltage category | II |
Insulating material group | II |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | >10⁸Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PUR |
Housing material | PUR |
Cable data | |
Sheath material | PVC |
Single-lead insulation | PVC |
Single-lead structure | 42 x 0,1 |
Cable diameter | 4.5 |
Conductor resistance | 57 Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 70 |
Temperature range, fixed cable, °C from | -25 |
Temperature range, fixed cable, °C to | 70 |
Bending radius, fixed cable | 28 mm |
Bending radius, moving cable | 45 mm |
Bending cycles | 2 Mio. |
Travel speed | At 5 m horizontal level up to 200 m/min. |
Approval 1 | UL listed |
UL style 1 | AWM2517 |
Customs tariff number | 85444290 |



Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
77 4429 0000 20003-0500
M12-B cable connector, Contacts: 3, not shielded, moulded on cable, IP68, UL listed, PVC black, 3 x 0,34 mm²
M12, series 766, Automation technology - data transmission and power supply
Order number |
77 4429 0000 20003-0500
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.34 mm² |
Wire gauge (AWG) | (22) |
Cable length | 5 m |
Degree of protection | IP68 |
Mechanical operation | > 100 Mating cycles |
Upper limit temperature | 90 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 4 A |
Rated voltage | 250 V |
Rated impulse voltage | 2500 V |
Pollution degree | 3 |
Overvoltage category | II |
Insulating material group | II |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | >10⁸Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PUR |
Housing material | PUR |
Cable data | |
Sheath material | PVC |
Single-lead insulation | PVC |
Single-lead structure | 42 x 0,1 |
Cable diameter | 4.5 |
Conductor resistance | 57 Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 70 |
Temperature range, fixed cable, °C from | -25 |
Temperature range, fixed cable, °C to | 70 |
Bending radius, fixed cable | 28 mm |
Bending radius, moving cable | 45 mm |
Bending cycles | 2 Mio. |
Travel speed | At 5 m horizontal level up to 200 m/min. |
Approval 1 | UL listed |
UL style 1 | AWM2517 |
Customs tariff number | 85444290 |



Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
77 4429 0000 20004-0200
M12-B cable connector, Contacts: 4, not shielded, moulded on cable, IP68, UL listed, PVC black, 4 x 0,34 mm²
M12, series 766, Automation technology - data transmission and power supply
Order number |
77 4429 0000 20004-0200
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.34 mm² |
Wire gauge (AWG) | (22) |
Cable length | 2 m |
Degree of protection | IP68 |
Mechanical operation | > 100 Mating cycles |
Upper limit temperature | 90 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 4 A |
Rated voltage | 250 V |
Rated impulse voltage | 2500 V |
Pollution degree | 3 |
Overvoltage category | II |
Insulating material group | II |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | >10⁸Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PUR |
Housing material | PUR |
Cable data | |
Sheath material | PVC |
Single-lead insulation | PVC |
Single-lead structure | 42 x 0,1 |
Cable diameter | 4.8 |
Conductor resistance | 57 Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 70 |
Temperature range, fixed cable, °C from | -25 |
Temperature range, fixed cable, °C to | 70 |
Bending radius, fixed cable | 28 mm |
Bending radius, moving cable | 45 mm |
Bending cycles | 2 Mio. |
Travel speed | At 5 m horizontal level up to 200 m/min. |
Approval 1 | UL listed |
UL style 1 | AWM2517 |
Customs tariff number | 85444290 |
Weight (g) | 84 |



Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
77 4429 0000 20004-0500
M12-B cable connector, Contacts: 4, not shielded, moulded on cable, IP68, UL listed, PVC black, 4 x 0,34 mm²
M12, series 766, Automation technology - data transmission and power supply
Order number |
77 4429 0000 20004-0500
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.34 mm² |
Wire gauge (AWG) | (22) |
Cable length | 5 m |
Degree of protection | IP68 |
Mechanical operation | > 100 Mating cycles |
Upper limit temperature | 90 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 4 A |
Rated voltage | 250 V |
Rated impulse voltage | 2500 V |
Pollution degree | 3 |
Overvoltage category | II |
Insulating material group | II |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | >10⁸Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PUR |
Housing material | PUR |
Cable data | |
Sheath material | PVC |
Single-lead insulation | PVC |
Single-lead structure | 42 x 0,1 |
Cable diameter | 4.8 |
Conductor resistance | 57 Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 70 |
Temperature range, fixed cable, °C from | -25 |
Temperature range, fixed cable, °C to | 70 |
Bending radius, fixed cable | 28 mm |
Bending radius, moving cable | 45 mm |
Bending cycles | 2 Mio. |
Travel speed | At 5 m horizontal level up to 200 m/min. |
Approval 1 | UL listed |
UL style 1 | AWM2517 |
Customs tariff number | 85444290 |
Weight (g) | 84 |



Security notices
- The connector must not be connected or separated under load. Non-observance and incorrect use can result in personal injury.
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
77 4429 0000 20005-0200
M12-B cable connector, Contacts: 5, not shielded, moulded on cable, IP68, UL listed, PVC black, 5 x 0,34 mm²
M12, series 766, Automation technology - data transmission and power supply
Order number |
77 4429 0000 20005-0200
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.34 mm² |
Wire gauge (AWG) | (22) |
Cable length | 2 m |
Degree of protection | IP68 |
Mechanical operation | > 100 Mating cycles |
Upper limit temperature | 90 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 4 A |
Rated voltage | 60 V |
Rated impulse voltage | 1500 V |
Pollution degree | 3 |
Overvoltage category | II |
Insulating material group | II |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | >10⁸Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PUR |
Housing material | PUR |
Cable data | |
Sheath material | PVC |
Single-lead insulation | PVC |
Single-lead structure | 42 x 0,1 |
Cable diameter | 5.7 |
Conductor resistance | 57 Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 70 |
Temperature range, fixed cable, °C from | -25 |
Temperature range, fixed cable, °C to | 70 |
Bending radius, fixed cable | 28 mm |
Bending radius, moving cable | 45 mm |
Bending cycles | 2 Mio. |
Travel speed | At 5 m horizontal level up to 200 m/min. |
Approval 1 | UL listed |
UL style 1 | AWM2517 |
Customs tariff number | 85444290 |
Weight (g) | 96 |



Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
77 4429 0000 20005-0500
M12-B cable connector, Contacts: 5, not shielded, moulded on cable, IP68, UL listed, PVC black, 5 x 0,34 mm²
M12, series 766, Automation technology - data transmission and power supply
Order number |
77 4429 0000 20005-0500
|
Connector locking system | bolted |
Termination | moulded on cable |
Wire gauge (mm) | 0.34 mm² |
Wire gauge (AWG) | (22) |
Cable length | 5 m |
Degree of protection | IP68 |
Mechanical operation | > 100 Mating cycles |
Upper limit temperature | 90 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 4 A |
Rated voltage | 60 V |
Rated impulse voltage | 1500 V |
Pollution degree | 3 |
Overvoltage category | II |
Insulating material group | II |
Volume resistivity | ≤ 3 mΩ |
Insulation resistance | >10⁸Ω |
Contact material | CuZn (brass) |
Contact plating | Au (gold) |
Contact body material | PUR |
Housing material | PUR |
Cable data | |
Sheath material | PVC |
Single-lead insulation | PVC |
Single-lead structure | 42 x 0,1 |
Cable diameter | 5.7 |
Conductor resistance | 57 Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 70 |
Temperature range, fixed cable, °C from | -25 |
Temperature range, fixed cable, °C to | 70 |
Bending radius, fixed cable | 28 mm |
Bending radius, moving cable | 45 mm |
Bending cycles | 2 Mio. |
Travel speed | At 5 m horizontal level up to 200 m/min. |
Approval 1 | UL listed |
UL style 1 | AWM2517 |
Customs tariff number | 85444290 |
Weight (g) | 96 |



Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
- To lock the cable connector to the equipment connector, the threaded ring is tightened until it is ‘finger-tight’ (approx. 50 cNm).
Downloads
Data sheet
Certificates
CAD files
Contact to customer service