Ordering no:
Connecting cable, Female power connector DIN EN 175301-803 - M12 angled connector , PUR 3x0,75 mm², wired, LED
Connecting cable, Female power connector DIN EN 175301-803 - M12 angled connector , PUR 3x0,75 mm², wired, LED, Series 210/A
Available numbers of contacts
79 5707 10 03
Size A connecting cord, Contacts: 2+2PE, not shielded, screw clamp, IP67, Standard cable, PUR black
M18, series 210, Automation technology - solenoid valve connectors
Order number |
79 5707 10 03
|
Connector locking system | central bolt |
Termination | screw clamp |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable length | 1 m |
Degree of protection | IP67 |
Mechanical operation | > 50 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 4 A |
Rated voltage | 24 V |
Rated impulse voltage | 800 V |
Pollution degree | 3 |
Overvoltage category | II |
Insulating material group | II |
Volume resistivity | ≤ 15 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze), CuZn (brass) |
Contact plating | Sn (tin) |
Contact body material | PA |
Housing material | PC |
Cable data | |
Sheath material | PUR |
Single-lead insulation | PVC |
Single-lead structure | 24 x 0,2 Cu |
Cable diameter | 6 |
Conductor resistance | 26Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 70 |
Temperature range, fixed cable, °C from | -25 |
Temperature range, fixed cable, °C to | 70 |
Bending radius, fixed cable | 30 mm |
Bending radius, moving cable | 60 mm |
Customs tariff number | 85444290 |
Weight (g) | 267.891 |



Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
79 5707 20 03
Size A connecting cord, Contacts: 2+2PE, not shielded, screw clamp, IP67, Standard cable, PUR black
M18, series 210, Automation technology - solenoid valve connectors
Order number |
79 5707 20 03
|
Connector locking system | central bolt |
Termination | screw clamp |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable length | 2 m |
Degree of protection | IP67 |
Mechanical operation | > 50 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 4 A |
Rated voltage | 24 V |
Rated impulse voltage | 800 V |
Pollution degree | 3 |
Overvoltage category | II |
Insulating material group | II |
Volume resistivity | ≤ 15 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze), CuZn (brass) |
Contact plating | Sn (tin) |
Contact body material | PA |
Housing material | PC |
Cable data | |
Sheath material | PUR |
Single-lead insulation | PVC |
Single-lead structure | 24 x 0,2 Cu |
Cable diameter | 6 |
Conductor resistance | 26Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 70 |
Temperature range, fixed cable, °C from | -25 |
Temperature range, fixed cable, °C to | 70 |
Bending radius, fixed cable | 30 mm |
Bending radius, moving cable | 60 mm |
Customs tariff number | 85444290 |
Weight (g) | 144.7 |



Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
Downloads
Data sheet
79 5705 10 03
Size A connecting cord, Contacts: 2+2PE, not shielded, screw clamp, IP67, Standard cable, PUR black
M18, series 210, Automation technology - solenoid valve connectors
Order number |
79 5705 10 03
|
Connector locking system | central bolt |
Termination | screw clamp |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable length | 1 m |
Degree of protection | IP67 |
Mechanical operation | > 50 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 4 A |
Rated voltage | 24 V |
Rated impulse voltage | 800 V |
Pollution degree | 3 |
Overvoltage category | II |
Insulating material group | II |
Volume resistivity | ≤ 15 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze), CuZn (brass) |
Contact plating | Sn (tin) |
Contact body material | PA |
Housing material | PC |
Cable data | |
Sheath material | PUR |
Single-lead insulation | PVC |
Single-lead structure | 24 x 0,2 Cu |
Cable diameter | 6 |
Conductor resistance | 26Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 70 |
Temperature range, fixed cable, °C from | -25 |
Temperature range, fixed cable, °C to | 70 |
Bending radius, fixed cable | 30 mm |
Bending radius, moving cable | 60 mm |
Customs tariff number | 85444290 |
Weight (g) | 88 |



Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
79 5705 20 03
Size A connecting cord, Contacts: 2+2PE, not shielded, screw clamp, IP67, Standard cable, PUR black
M18, series 210, Automation technology - solenoid valve connectors
Order number |
79 5705 20 03
|
Connector locking system | central bolt |
Termination | screw clamp |
Wire gauge (mm) | 0.75 mm² |
Wire gauge (AWG) | 20 |
Cable length | 2 m |
Degree of protection | IP67 |
Mechanical operation | > 50 Mating cycles |
Upper limit temperature | 85 °C |
Lower limit temperature | -25 °C |
Rated current (40 °C) | 4 A |
Rated voltage | 24 V |
Rated impulse voltage | 800 V |
Pollution degree | 3 |
Overvoltage category | II |
Insulating material group | II |
Volume resistivity | ≤ 15 mΩ |
Insulation resistance | ≥ 10¹⁰Ω |
Contact material | CuSn (bronze), CuZn (brass) |
Contact plating | Sn (tin) |
Contact body material | PA |
Housing material | PC |
Cable data | |
Sheath material | PUR |
Single-lead insulation | PVC |
Single-lead structure | 24 x 0,2 Cu |
Cable diameter | 6 |
Conductor resistance | 26Ω/Km |
Temperature range, moving cable, °C from | -5 |
Temperature range, moving cable, °C to | 70 |
Temperature range, fixed cable, °C from | -25 |
Temperature range, fixed cable, °C to | 70 |
Bending radius, fixed cable | 30 mm |
Bending radius, moving cable | 60 mm |
Customs tariff number | 85444290 |
Weight (g) | 147.5 |



Security notices
- The connectors are designed for use in plant, control system and electrical equipment. The end user is responsible for checking whether the connectors are suitable for use in other applications.
- Connectors with degree of protection IP 67 and IP 68 are not suitable for use under water. When used outdoors, the connectors must be separately protected against corrosion. For further information about IP degrees of protection refer to ‘Technical support’ in the Download Centre.
Contact to customer service
Do you have any questions regarding our products or do you wish an individual offer?